+86 571 88675528 CN
CN
Return Superior Enquiry
Overview
NanoAccu S MicroSpectrophotometer

180~910nm 丨<6 秒

Features
1.7-inch touched screen, Android system with friendly UI design
2.Quick detection (only takes time of 2-6s), no dilution needed
3.Auto-detection function is available
4.No need to preheat instrument, measurements can be done upon turning on
5.Long life's Xenon flash lamp,109 flashes
6.Good repeatability due to accurate pathlength control
7.Heating up to 37℃ , stirring speed 100-900rpm for cuevette measurements
8.Only 0.5 ~ 2μl sample volume requested, which can be recycled after test, ideal for precious samples
9.Fluorometer measurement, strong specificity, high sensitivity can make it detect low concentration samples like dsDNA、Oligo、RNA、 protein, down to 0.5pg/μl(dsDNA High Sensitivity)
10.Built-in printer
11.Measurement results can be exported to U disc in format of Excel、JPG
Description
Technical Parameters

  •  Sample Volume

    0.5μl~2μl, advice 2μl

  • Wavelength Range

    180~910nm

  • Wavelength Accuracy

    ±1nm

  • Spectral Resolution

    ≤ 1.5nm(FWHM@Hg 253.7nm)

  • Absorbance Range

    0.04~750(260nm 波长下,等同于 10mm光程时) 

  • Absorbance Precision

    0.002Abs (1mm WaveLength)

  • Absorbance Accuracy

    ±1%(7.332 at260nm)

  • Measurement Time

    <6s 

  • Path Length

    0.03mm、0.1mm、0.2mm、1mm、1.2mm

  • Light source / Life

    Xenon / Flashes >109

  • Concentration Range

    2 ~37500ng/ul dsDNA;1.32~24750 ng/μL ssDNA ;1.6~30000ng/μL RNA

  • Protein Detection  Range

    BSA 0.06 ~ 1119mg/ml;IgG 0.03 ~ 547mg/ml ;A280 0.04~750mg/m1 ;Lysozyme 0.015~284mg/ml

  • Detector

    2048 -element linear CMOS array

  • Sample pedesta

    304 Stainless steel and Quartz fiber

  • Power Adaptor

    DC12V 4A

  • Power

    48W

  • Dimension(W×D×H) 

    300x232x196mm

  • Weight

    3.8 kg

  • OD600 Absorbance  Range 

    0~4.000 Abs

  • OD600 Absorbance Stability 

    (0,3)≤ 0.5%, [3,4)≤ 1.5% 

  • OD600 Absorbance Repeatability

    (0,3)≤ 0.5%, [3,4)≤ 1.5%

  • OD600 Absorbance Accuracy 

    (0,2)≤ 0.005A,[2,3)≤ 1%,[3,4)≤ 2%

  • OD600 Heating up

    37℃

  • OD600 Stirring speed

    100-900rpm

  • Fluorometer Sample Volume

    1-20μl

  • Fluorometer Measurement Time

    3s

  • Fluorometer Repeatability

    < 1.5%

  • Fluorometer orders of magnitude of concentration

    5

  • Fluorometer Concentration Range

    0.01ng/μl-120ng/μl dsDNA HS 0.2ng/μl-2000ng/μl dsDNA BR 0.05ng/μl-240ng/μl Oligo 0.1mg/ml-20mg/ml proteinBR

  • Fluorometer Linear dynamic range

    R2≥ 0.995

  • Fluorometer Light Source

    LED

  • Fluorometer Excitation wavelength

    470/625 (Standard) 365/525 (Optional)

  • Fluorometer Emission wavelength

    525/690 (Standard) 460/620 (Optional)

Enquiry
Title*
Name*
Telephone*
Mail*
Submit
Reset
NanoAccu S MicroSpectrophotometer